Abstract:
Miniaturized, easily integrated thin-film gas sensors with high consistency, stability, and suitability for mass production are crucial for non-invasive breath analysis. A series of GaN-based thin-film sensors with high stability and excellent sensing capabilities prepared by Metal-organic Chemical Vapor Deposition, in which the n-GaN sensor exhibited an ultra-low detection limit of 100 ppt for NO2, and 2 ppb for NO, the InGaN sensors with different In composition manifest good response to reducing gases of NH3 and TMA. The shift trend of selectivity for the sensors from oxidizing gases to reducing gase. can be attributed to the mutative relative content of the lattice oxygen/adsorbed oxygen ratio by adjusting the In composition, which is based on the in situ characterization results. The sensors exhibit excellent hydrophobicity, significantly enhancing their reliability in exhale gas sensing under high-humidity conditions. Response mapping model through mixed-gas training improved cross-sensor compatibility and enhanced model generalization. Herein an integrated multimodal sensor system combining a sensor array with a temperature and humidity sensor is proposed and developed alongside a dual-channel exhaled breath collection system. Utilizing a Time Sequence Analysis model, this integrated system enables non-invasive diagnosis of lung cancer patients.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...