Related Experiment Video
Updated: Jan 11, 2026

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
Published on: December 27, 2012
Broadband Absorbers Measurement Based on Wavelength Modulation Spectroscopy with Logarithmic Transformation and
Rui Wang1, Liqun Sun1, Xuan Wang2
1Tsinghua University, Department of Precision Instruments, Beijing 100084, China.
Abstract:
We proposed a method for measuring the concentration of broadband absorbers based on wavelength modulation spectroscopy (WMS), logarithmic transformation of the absorption signal, and analysis of the first harmonic (1f) signal. We found that the second harmonic (2f) signal of broadband absorbers is weak, while the 1f signal is much stronger. However, conventional WMS relies on an idealized Voigt absorption line profile for approximation, while the demodulated 1f signal intensity remains concentration-independent. Thus, we proposed a modified WMS method in which, through logarithmic transformation of the absorption signal, the intensity of the 1f signal is linear to the absorbance regardless of the gas absorption line shape. This allowed for the retrieval of broadband absorbers' concentration by measuring the 1f signal. To locate the detection wavelength, we introduced a reference gas that exhibits a narrow absorption peak within the absorption band of the broadband absorbers and utilized the peak of its 2f signal for wavelength calibration. We validated the effectiveness of the method by experiments, where isobutane was measured while ethane was selected as the reference gas. The 1f signal intensity demonstrated a strong linear correlation with isobutane concentration across different ethane background concentrations (R2 =0.9989). Based on Allan deviation analysis, the system achieved a minimum detectable concentration of 97 ppb at the optimal averaging time of 19.7 s. Compared to the 2f-based approach, the 1f-based method improved the detection limit by more than 40 times.
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectrometers
UV–Vis Spectroscopy: Beer–Lambert Law
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

