Related Experiment Video
Updated: Apr 30, 2026

Using Retinal Imaging to Study Dementia
Published on: November 6, 2017
Real-World Prospective Validation and Economic Evaluation of Deep Learning- Based Diabetic Retinopathy Detection From
An Ran Ran1, Jennifer Li Ding2, Ziqi Tang1
1Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong SAR, China.
Background:
Deep learning (DL) has shown promise in delivering diagnostic and economic benefits for detecting diabetic retinopathy (DR) from fundus photographs (FPs). However, evidence synthesis of model validation in prospective, real-world settings remains limited.
Purpose:
To assess the feasibility of implementing DL-DR systems using FPs across different countries by synthesizing prospective validation and economic evidence.
Data Sources:
Five databases were searched until 13 August 2025.
Study Selection:
Studies prospectively assessing diagnostic performance and/or studies conducting economic analyses of DL-DR systems using FPs were selected.
Data Extraction:
Characteristics of all studies, performance parameters of prospective validation studies, and economic outcomes of economic analysis studies were extracted.
Data Synthesis:
Forty-seven studies were included in the meta-analysis. The pooled performance was the highest in detecting vision-threatening DR (area under the receiver operating characteristic curve [AUROC] 0.974), followed by any DR (AUROC 0.965), then referable DR (RDR) (AUROC 0.959). Study region, clinical pathway, mydriasis, image quality control, sample size, grading criteria, reference standard, and model architecture significantly affected model performance in RDR detection. Fifteen studies were included in the economic commentary, showing that DL-based DR screening was cost-effective in high-income countries, whereas results in middle-income countries were mixed, depending on compliance rates, glycemic control, and initial costs.
Limitations:
A paucity of studies assessing multiple severities of DR or diabetic macular edema restricted our ability to perform subgroup analyses. Insights into low-income countries were limited by a lack of studies in these regions.
Conclusions:
DL-DR systems using FPs had high discriminative performance in prospective real-world settings and hold promise to improve cost-effectiveness, especially in high-income countries.