Correlation of the Six-Minute Walk Test, Diffusing Capacity for Carbon Monoxide, and Pulmonary Function Parameters in
Sushant Muley1, Sushant Meshram1, Avinash Gandhare1
1Department of Pulmonary Medicine, Government Medical College, Nagpur, Nagpur, IND.
Abstract:
Background Interstitial lung disease (ILD) encompasses a broad group of progressive lung disorders marked by inflammation and fibrosis, leading to irreversible damage. Early screening plays a pivotal role in identifying disease onset and optimizing patient outcomes. This study assessed the correlation of diffusing capacity for carbon monoxide (DLCO) with the six-minute walk test (6-MWT) and pulmonary function test (PFT) parameters. Moreover, the correlation between 6-MWT and PFT parameters was evaluated. Methods This cross-sectional study, involving 30 patients with high-resolution computed tomography-proven ILD, was performed over a period of 24 months (October 2022 to September 2024) in the Department of Respiratory Medicine of Government Medical College, Nagpur, in Nagpur, India. All patients underwent 6-MWT and PFT. Vital parameters were assessed before and immediately after 6-MWT, and the six-minute walk distance (6-MWD) was calculated. Results 6-MWT had a weakly positive and significant correlation with forced vital capacity (FVC) (r=0.38; p=0.037), but not with forced expiratory volume in one second (FEV1) and DLCO (p>0.05). DLCO had a positive and non-significant correlation with total lung capacity, FEV1, and FVC, while correlation with FEV1/FVC ratio was negative and non-significant (p>0.05). Actual 6-MWD was significantly lower than the predicted value (p<0.001). Immediately after 6-MWT, there was a significant decrease in oxygen saturation, while systolic blood pressure, pulse rate, and respiratory rate increased significantly compared to baseline 6-MWT values (p<0.001), with diastolic blood pressure being comparable at both intervals (p>0.05). Conclusion 6-MWT had a weak but significant correlation with FVC, while the correlation between other parameters was not significant. These tests highlight functional limitations and physiological derangements, thus strengthening their role in ILD management.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Chronic Obstructive Pulmonary Disease-I: Introduction
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...