Related Experiment Video
Updated: Jan 10, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Pressure-induced taste and odour deviations within the high-pressure drinking water distribution system
Zoë Mol1, Lore Segers2, Herman Van Langenhove2
1Research Group Environmental Organic Chemistry and Technology (EnVOC), Department of Green Chemistry and Technology, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium; Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Frieda Saeysstraat 1, B-9052 Ghent, Belgium.
Abstract:
Taste and odour (T&O) issues in tap water decrease the willingness of consumers to drink it. Production and/or release of odour compounds during drinking water distribution should be avoided as the water is directly delivered to consumers without further treatment. Odours can be caused by leaching of compounds from pipe materials, microbial metabolism, disinfection reactions, or diffusion of odour compounds or precursors from external sources. Increasing knowledge of T&O origins is needed to better solve future problems. Therefore, this research focuses on odour linked to changes in pressure because of maintenance work at the high-pressure (HP) drinking water distribution system. A trace analytical method targeting 45 T&O compounds is further optimized by including derivatisation to improve halophenol detection. Next, in a field section of a real HP pipe (± 3 km), three scenarios were systematically investigated. Lowering the overpressure in the HP pipe from 10 to 5 bar resulted in an observed bitumen/asphalt odour, that further increased in intensity after a subsequent sudden pressure drop to 2 bar. Based on the odour threshold and profile, two halophenols were detected that may have contributed to this odour observation. When the section was partially emptied, 6 halophenols and 5 other T&O compounds were identified. Our results indicate that pressure changes induce the leaching of T&O compounds from sealing materials connecting the 6m-pipe sections. This is further supported by the detection of similar T&O compounds in a water extract of the sealing materials and in an odorous household sample collected after maintenance work in the HP-network.
More Related Videos
06:19Author Spotlight: Implications of Non-Nutritive Sucking on Speech Emergence and Infant Development
Published on: April 19, 2024
10:06Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO2 Foam Transport in Fractured Unconventional Reservoirs
Published on: July 2, 2020
Related Concept Videos
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Design Example: Designing a Residential Plumbing System
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Osmosis and Osmotic Pressure of Solutions
Concept of Pressure at a Point
In a fluid at rest, pressure acts equally in...