Jiancheng dual-channel vs. i-gel laryngeal mask airway for fiberoptic bronchoscopy: A randomized trial
Ru-Ping Dai1, Wei Luo1, Wen Wang2
1Department of Anesthesiology, The Second Xiangya Hospital, Central South University, Changsha, China; Anesthesia Medical Research Center, Central South University, Changsha, China.
Background:
Fiberoptic bronchoscopy (FB) procedures have become increasingly lengthy and complex. Maintaining deep sedation while preventing hypoxemia with conventional oropharyngeal/nasopharyngeal airways presents a significant clinical challenge. Supraglottic airway devices, such as the laryngeal mask airway (LMA), may provide improved oxygenation and procedural efficiency during FB. However, despite the variety of LMA designs, no previous studies have definitively established the optimal type of LMA for FB procedures.
Methods:
96 patients were randomized to either the i-gel LMA group (group I) or Jiancheng dual-channel LMA group (group J). Remimazolam besylate, ciprofol, and sufentanil were used for anesthesia induction and maintenance in both groups. We measured and recorded the success rate of LMA insertion and entering the main airway through the LMA at first attempt, operational interference, mid-procedure LMA adjustments, procedure interruptions, vital signs, and major adverse events.
Results:
The patients in group J experienced higher success rates of first-attempt LMA insertion (P < 0.01) and entry into the main airway (P < 0.01) than those in group I. The incidence of coughing was significantly higher in group I than in group J (P < 0.01). The incidence of cardiopulmonary adverse reactions, including respiratory arrest, airway obstruction, airway spasm, laryngospasm, hypertension, and hypotension, was comparable between the two groups. Group I demonstrated a tendency toward prolonged recovery time compared with group J (P = 0.05).
Conclusions:
The Jiancheng dual-channel LMA is associated with higher first-attempt success for airway insertion and bronchoscopy compared to the i-gel LMA, warranting consideration for broader clinical application.
Trial Registration:
https://www.chictr.org.cn/showproj.html?proj=265357 (registration no. ChiCTR2500100990, principal investigator: Ru-Ping Dai, date of registration: April 17, 2025).
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...