Related Experiment Video
Updated: Jul 8, 2026

Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
Published on: October 17, 2016
Multi-stage convo-enhanced retinex canny DeepLabv3+ FusionNet for enhanced detection and classification of bleeding
1School of Computer Science and Engineering, Vellore Institute of Technology, Chennai Campus, Vandalur - Kelambakkam, Chennai, 600127, Tamilnadu, India.
Abstract:
Detection of gastrointestinal bleeding in Wireless Capsule Endoscopy (WCE) images and accurate bleeding region segmentation and classification is crucial for exact diagnosis and treatment, as early detection can prevent severe complications. However, it remains challenging due to the inability of current methods to effectively differentiate between types of bleeding and handle complex borders of lesions. In this paper, a new framework: Multi-Stage Convo-Enhanced Retinex Canny DeepLabV3+ FusionNet is proposed to better tackle these challenges. Existing feature extraction algorithms struggle with colour differentiation and texture recognition, often failing to miss fine-scale textures that distinguish active bleeding from coagulated blood effectively. Hence, this approach is initiated with Clip-BiRetinexNet for preprocessing, enhancing image contrast and color consistency using Clipped Histogram Equalization and Bilateral Filtered Retinex thereby capturing fine-scale textures that distinguish active bleeding from coagulated blood. Existing segmentation and classification methods struggle with irregular and complex borders of bleeding types like ulcers and vascular lesions due to ineffective border detection. Therefore, the segmentation in this proposed model is handled by Hough Canny-Frangi Enhanced DeepLabV3+, improving edge detection and vascular pattern enhancement to delineate accurately irregular lesions. Next, a ResNet-NaiveBayes Fusion was shown for classification, offering effective probabilistic classification. The implementation results show that the proposed approach outperforms the state-of-the-art methods with a high mean pixel accuracy of 97.6%, classification accuracy of 99.2% and Dice Similarity Coefficient of 99.6%.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies VII: Vascular Imaging

