Load-deflection characteristics of Damon™ Ultima vs heat-activated NiTi wires in passive self-ligating brackets: An
Sayed Abdul Hadhi1, Monis Raza1, Achint Juneja1
1Department of Orthodontics and Dentofacial Orthopaedics, Institute of Dental Studies & Technologies, Kadrabad, Modinagar, 201201, Ghaziabad U.P., India.
Objective:
To evaluate the load-deflection characteristics of Damon™ Ultima (0.014×0.0275") wires compared with heat-activated nickel-titanium (HANT, 0.014×0.025") wires across different passive self-ligating brackets (PSLBs).
Material And Methods:
One hundred eight bracket-wire assemblies were allocated into six groups based on three PSLB systems (Damon™ Ultima, Damon™ Q, Unitek™ Gemini SL) and two wire types. A modified ISO 15841 three-point bending test was performed at 37̊C using an Instron machine, with deflections recorded at 0.5mm steps from 3.0 to 0.5mm. A supplementary wet-after-thermocycling protocol (5000 cycles; artificial saliva) assessed ecological validity. Statistical analysis (SPSS v23) included t-tests, one-way ANOVA/Kruskal-Wallis tests, and effect-size estimation (Cohen's d, Hedges' g) with 95% confidence intervals; multiple comparisons were adjusted using the Holm-Bonferroni method.
Results:
Damon™ Ultima wires produced significantly lower deactivation forces than HANT wires across PSLBs at 1.0- and 1.5-mm deflections (P<0.001). Activation differences were bracket-dependent, with significant reductions observed mainly in Damon™ Ultima brackets. Wet-after-thermocycling reduced deactivation forces by 23-37% at 1.0-1.5mm, with large paired effect sizes (Hedges'g ≈-1.5 to-1.9). Force delivery remained light and consistent despite the larger 0.0275″ cross-section.
Conclusion:
Within the limits of this bench study, Damon™ Ultima wires exhibited lower unloading forces at clinically relevant deflections across PSLBs, potentially facilitating earlier bracket engagement and rotational efficiency. However, rotational control was not directly measured, and clinical trials are warranted to validate these findings.
More Related Videos
08:46Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Charging Conductors By Induction
Generally, conductors like metals do not allow any excess charge to be present on them. Any excess charge added to metals easily flows away, for example, when a metal is placed on the Earth. This process is called earthing.
However, conductors can be charged by a process called induction. For example, consider charging a...
Magnetic Force On Current-Carrying Wires: Example
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load
The Electrical Double Layer