Abstract:
Cobalt (Co) and chromium (Cr) are widely used in medical implants due to their strength and biocompatibility. However, implant wear and corrosion can lead to systemic release of these metals, raising concerns about cardiotoxic effects, especially with long-term exposure. This review summarizes current data on the potential cardiotoxicity of implant-derived Co and Cr, focusing on molecular mechanisms, inflammatory responses, and clinical observations. Case reports and clinical studies document considerable variability in serum Co and Cr concentrations postimplantation, influenced by implant type, material composition, and patient-specific factors. While extreme elevations are strongly associated with cardiomyopathy and fibrosis, moderate increases also correlate with subclinical changes such as ventricular dilatation and impaired strain. Nonetheless, many studies fail to find a direct relationship between ion levels and cardiac dysfunction, highlighting the complexity and interindividual variability of toxic responses and underlying pathomechanisms. Existing experimental data suggest that Co and Cr ions interfere with calcium and magnesium handling, impair mitochondrial respiration, and promote the generation of reactive oxygen species. Additionally, both metals can induce inflammatory responses, including cytokine release that results in DNA damage, apoptosis, and impaired cardiomyocyte physiology. Although Co and Cr implants offer substantial clinical benefits, emerging evidence indicates that they may contribute to cardiotoxicity in susceptible individuals. Current findings emphasize the importance of personalized monitoring, including serum ion concentration assessments and advanced imaging techniques. Given the absence of universally accepted toxicity thresholds, further mechanistic and longitudinal clinical studies are essential to define risk stratification strategies, establish safe exposure limits, and improve the cardiovascular safety of patients with metal implants.
More Related Videos
09:08Biotribological Testing and Analysis of Articular Cartilage Sliding against Metal for Implants
Published on: May 14, 2020
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
The Periodic Table and Organismal Elements
Periodic Table Provides Information...
Imaging Studies for Cardiovascular System IV: CMRI
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Complexation Equilibria: The Chelate Effect