Related Experiment Video For adenoma
Updated: Jan 10, 2026

Competing-Risk Nomogram for Predicting Cancer-Specific Survival in Multiple Primary Colorectal Cancer Patients after Surgery
Published on: September 27, 2024
Colorectal polyp count discrepancies and their impact on colonoscopy surveillance interval decisions: a retrospective
Lokman Cevik1, Wei Chen1, Denise Gamble1
1Department of Pathology, The Ohio State University Wexner Medical Center, Columbus, OH, United States.
Objective:
Colorectal cancer surveillance recommendations rely on polyp counts to determine optimal intervals. This study aims to uncover discrepancies in polyp counts between colonoscopy and pathology reports and their clinical implications.
Methods:
A retrospective review of 1293 polyp cases from October 1 to December 31, 2019, was performed, comparing the reported number of polyps removed to the number identified pathologically (gross and microscopic). Cases with discrepant polyp counts prompted additional reviews, including colonoscopy reports and glass slides. The potential impact on surveillance interval decisions was further assessed.
Results:
Of the 1293 polyp specimens from 600 patients, 1072 (83%) contained a single polyp per container, with no discrepancies. However, in the remaining 221 (17%) specimens that had multiple polyps submitted per container, an exact polyp count was indeterminable in 54 (24%) of these 221 specimens. Among these, polyp count discrepancies in 15 patients potentially influenced surveillance intervals. Overall, the most common discrepancy was a higher number of fragments on gross description and/or glass slides compared to colonoscopy reports and/or a container designator.
Conclusions:
Discrepancies in polyp counts more often occur when more than 1 polyp is submitted in a single container. These discrepancies may alter the recommended surveillance colonoscopy intervals. Therefore, close collaboration between pathology and colonoscopy providers-through improved endoscopic documentation, specimen handling, reporting strategies, and feedback-is essential to ensure accurate polyp counts and mitigate these effects. Adopting a single polyp per container approach in those cases where polyp count matters would significantly improve report accuracy and ensure the most appropriate surveillance intervals.
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...