Related Experiment Video
Updated: May 5, 2026

A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
Evaluation of the Diagnostic Accuracy of the Quantitative Point-of-Care SD Biosensor Standard G6PD Test for
Flavia Regina Medeiros da Silva1, Alexandre Gomes Vizzoni1, Daniela Mendes-de-Almeida1
1Hematology and Hemotherapy Service, Evandro Chagas National Institute of Infectious Diseases (INI), Oswaldo Cruz Foundation, Rio de Janeiro, Brazil.
Background:
G6PD deficiency affects about 500 million people worldwide and is prevalent in many malaria-endemic settings. People with G6PD deficiency are at risk of hemolysis when exposed to certain medications, including 8-aminoquinoline drugs used to treat Plasmodium vivax malaria. Increasing access to testing for G6PD deficiency at or near the point of care is critical to expanding the safe treatment of P. vivax malaria. We aimed to evaluate the performance of a semiquantitative test for G6PD deficiency, the SD Biosensor Standard G6PD Test with the Brewer's method, in a reference site for the treatment of infectious diseases.
Method:
We evaluate the diagnostic accuracy performance of the SD Biosensor Standard G6PD Test in 125 individuals with infectious diseases and other illnesses.
Main Results:
We observed a trend of concordance between the G6PD status (Deficient or Normal), with low frequencies of discordances in the screenings. The strength of agreement between G6PD tests was classified as almost perfect in all participants (k = 0.82, 95% CI = 0.66, 0.97) and in sex subgroups: females (k = 0.83, 95% CI = 0.59, 1.00) and males (k = 0.81, 95% CI = 0.59, 1.00). The total concordance percentage (number of concordances/total) was 95% for females, 97% for males, and 96% overall.
Conclusion:
The SD Biosensor STANDARD G6PD test is an innovative point-of-care solution. It offers quantitative measurement of glucose-6-phosphate dehydrogenase activity while normalizing for hemoglobin levels. This advancement enables its use in lower-tier clinical and laboratory settings, expanding access to accurate G6PD testing.