Related Experiment Video
Updated: Jan 10, 2026

Olfactory Assays for Mouse Models of Neurodegenerative Disease
Published on: August 25, 2014
Validity and Reliability of the French Olfactory Disorders Questionnaire-10
Jérôme R Lechien1,2,3,4,5, Luigi A Vaira5,6,7, Lea Lamoulen8
1Department of Surgery, Faculty of Medicine, UMONS Research Institute for Health Sciences and Technology, University of Mons, Mons, Belgium.
Abstract:
ImportanceMost French Olfactory Questionnaires are time consuming, which may affect the patient participation.ObjectiveTo validate a short French version of the Olfactory Disorders Questionnaire (Fr-ODQ).DesignProspective controlled study.SettingMulticenter study.ParticipantsPatients with long-lasting olfactory dysfunction (OD) treated with platelet-rich plasma into the olfactory clefts and asymptomatic subjects.InterventionDevelopment and validation of a short ODQ.Main OutcomesIndividuals completed the full Fr-ODQ. The Threshold, Discrimination, and Identification (TDI) test was performed in OD patients. A combined statistical analysis was performed to determine the most informative items of the Fr-ODQ to develop a shorter version. The internal consistency was determined with Cronbach's alpha. The reliability and external validity were evaluated through a test-retest approach and by correlating with the Fr-ODQ. Both the minimal clinically important difference (MCID) and the threshold of the short ODQ version were determined.ResultsA total of 263 patients (173 [65.8%] females) and 129 controls (92 [71.3%] females) completed the evaluations. The mean age of patients was 51.2 ± 15.3 years. The mean duration of OD was 42.4 ± 54.3 months. The biostatistical models selected 10 essential items composing the Fr-ODQ-10. The baseline Fr-ODQ-10 was significantly correlated with the TDI (rs = 0.228; P = .001) and the Fr-ODQ (rs = 0.875; P = .001), demonstrating high external validity. Fr-ODQ-10 was significantly lower in controls compared to OD patients (P = .001), highlighting high internal validity. The internal consistency was good (α = .796). The external consistency was adequate, with significant correlations between the test-retest Fr-ODQ-10. The Fr-ODQ-10 significantly decreased from baseline to 4 months post-treatment. A Fr-ODQ-10 score >7.5 was considered abnormal (sensitivity: 84.8%, specificity: 84.2%). The MCID of Fr-ODQ-10 was established at >3.Conclusion and RelevanceThe Fr-ODQ-10 is a valid and reliable clinical instrument, demonstrating correlation with the psychophysical olfactory assessment.
Related Concept Videos
Reliability and Validity
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Olfactory Receptors: Location and Structure
Self-Report Tests of Personality
Olfaction
The olfactory receptors are embedded in the cilia of the...

