Related Experiment Video
Updated: Jan 10, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Comparing Cardiac Output Differences in Patients With Fontan Physiology Between High and Low Tidal Volume Strategies:
P S Adams1, L M Stollings1, S Bains1
1UPMC Department of Anesthesiology and Perioperative Medicine, Division of Pediatric Cardiac Anesthesiology, UPMC Children's Hospital of Pittsburgh, Pittsburgh, PA, USA.
For single ventricle heart disease patients on mechanical ventilation, lower tidal volumes may be better for maintaining cardiac output. This study found no significant difference, but trends suggest lower volumes are favorable.
Area of Science:
- Pediatric Cardiology
- Critical Care Medicine
- Cardiovascular Physiology
Background:
- Patients with single ventricle congenital heart disease (CHD) palliated to Fontan physiology lack a native ventricle for pulmonary blood flow.
- Positive pressure mechanical ventilation can reduce cardiac output in these patients compared to negative pressure ventilation.
- Optimal tidal volume settings for mechanical ventilation in Fontan patients remain controversial.
Purpose of the Study:
- To determine if higher or lower tidal volumes are optimal for systemic cardiac output in pediatric Fontan patients.
- To compare systemic cardiac index (CI), pulmonary blood flow, and vascular resistances under different tidal volume strategies.
Main Methods:
- A crossover trial involving pediatric Fontan patients (<18 years) requiring mechanical ventilation during cardiac catheterization.
- Patients were randomized to initial high (10 mL/kg) or low (6 mL/kg) tidal volume ventilation strategies.
- Systemic CI, pulmonary blood flow, and vascular resistances were compared between ventilation strategies.
Main Results:
- Thirty patients completed the study. A higher cardiac index was observed in the low tidal volume strategy for more patients (42%) compared to the high tidal volume strategy (33%).
- No statistically significant difference in mean cardiac index was found between low (3.19 L/min/m² ) and high (2.96 L/min/m²) tidal volume strategies (p=0.062).
- The study was powered to detect a clinically significant difference of 0.7 L/min/m².
Conclusions:
- Direct comparison showed no significant difference in cardiac index between high and low tidal volume strategies in Fontan patients.
- Data suggest that lower tidal volume ventilation may be beneficial for maintaining cardiac index in some Fontan patients requiring positive pressure ventilation.
More Related Videos
06:10Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...