A clinical grade neurostimulation implant for hierarchical control of physiological activity
Moaad Benjaber1,2, Mayela Zamora1,2, Robert Toth1,2
1Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.
Abstract:
Bioelectronic implants for neurostimulation aim to steer disordered neurophysiological processes back towards a healthy state. However, physiology is subject to biological rhythms, including the circadian rhythm and the sleep-wake cycle. These predictable rhythms affect disease symptomatology, biomarkers used in closed-loop therapies, and a physiological system's expected response to stimulation. Therefore, therapeutic devices should incorporate feedforward elements to align algorithm parameters with predictable changes in physiological state, as a parallel of physiological rheostatic control. Here we introduce the DyNeuMo-2c, the first clinical-grade implant capable of delivering closed-loop neurostimulation while flexibly changing its functional configuration according to time of day. The device can chronically measure brain activity and motion state to track potential biomarker patterns in natural, out-of-clinic settings, allowing identification and targeting of patient-specific chronotypes. The system implements a hierarchical control flow, with baseline therapy set by a circadian scheduler, and adaptive policies layered to take effect based on specific biomarkers indicating patient and disease state. Using a benchtop validation setup, we demonstrate that the system has the required capabilities for delivering time-contingent closed-loop therapy in two established clinical use cases: Parkinson's disease and epilepsy. Next, we deploy the system in vivo to deliver closed-loop deep brain stimulation in a healthy non-human primate model of vigilance, highlighting the importance of synchronisation between device operation and physiological state in various conditions (task performance, unconstrained behaviour, and sleep). Time-of-day-dependent adaptation of closed-loop stimulation enabled modulation of both vigilance and behaviour. Overall, the novel device architecture provides a proof-of-concept for delivering time-contingent therapy in chronic therapeutic settings where biological rhythms are of key importance.
More Related Videos
09:27A Method for Systematic Electrochemical and Electrophysiological Evaluation of Neural Recording Electrodes
Published on: March 3, 2014
08:42The DREAM Implant: A Lightweight, Modular, and Cost-Effective Implant System for Chronic Electrophysiology in Head-Fixed and Freely Behaving Mice
Published on: July 26, 2024
Related Concept Videos
Ligand-gated Ion Channels
Three Subfamilies of Ligand-gated Ion Channels
Ligand-gated ion channels fall into three subfamilies. The 'Cys-loop' includes the nicotinic acetylcholine receptors, γ-aminobutyric acid (GABA), glycine, and 5-hydroxytryptamine receptors. The second one is the 'Pore-loop' channels that include the...
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Neurochemical Transmission: Sites of Drug Action
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Pain