Related Experiment Video
Updated: Jan 10, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Baselines Matter: Mass Spectrometric Assessments of Biological O2 Supersaturation (ΔO2:Ar) Benefit from Two-Point
Sebastian D Rokitta1, Emelia J Chamberlain2, Alessandra D Angelo3
1Alfred-Wegener-Institute─Helmholtz-Centre for Polar and Marine Research, 27570 Bremerhaven, Germany.
None:
Membrane-inlet mass spectrometry (MIMS) based assessments of ΔO2:Ar to estimate marine productivity are becoming a widely used tool in biogeochemistry. Especially continuous ship-borne surveys of dissolved gases allow for high spatial and temporal resolution in the analysis of surface ocean net community productivity. Depending on instrument configuration and architecture, however, measurements may be afflicted with substantial detection baselines for each analyzed gas. We hypothesized that ignoring these baselines (as seems to be common practice) can considerably affect the outcomes of the measurements. Using MIMS data from two cruises, we assessed the impact of calibration procedures and different pressure regimes, i.e., gas loads, on the ΔO2:Ar ratios and analyses of net community productivity. We compared conventional ratio-based one-point calibration approaches with two-point calibration approaches that include baselines and either calibrate for the equilibrium ratio of O2:Ar, or calibrate for the individual gas concentrations. Our data show that higher gas loads increase apparent signal heights, but also disproportionately increase the individual gas-associated baseline levels, thereby reducing instrument sensitivity while increasing a potential bias if data is used without correction. Depending on the adjusted gas loads, severe underestimations of final ΔO2:Ar values by factors of ca. 1.4 and 4 were calculated when disregarding baselines, emphasizing the critical importance of baseline determinations in MIMS-based methods.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Tandem Mass Spectrometry
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Mass Spectrometry: Overview
Mass Spectrometry: Isotope Effect
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

