Related Experiment Video
Updated: Jun 30, 2026

Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
Published on: April 14, 2014
Utility of transorbital ultrasound to assess disability and axonal loss in multiple sclerosis
Poornima Nair1, B Srikumar2, M S Sunil3
1Department of Neurology, Government Medical College, Thiruvananthapuram, Kerala, India. pnairbhavana@gmail.com.
Background:
In multiple sclerosis (MS), axonal damage plays a significant role in contributing to disability. This study assesses the diagnostic accuracy and use of transorbital sonography (TOS) as a surrogate for axonal loss by measuring the optic nerve diameter (OND) and optic nerve sheath diameter (ONSD).
Methodology:
It was a cross-sectional study in the Neurology Department, Government Medical College, Thiruvananthapuram. MS patients were enrolled, and expanded disability status scale (EDSS) scores assessed their disability. Disability was defined as EDSS > 2. OND and ONSD were measured using TOS. The retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were measured using optical coherence tomography (OCT). We constructed receiver operating characteristics curve using RNFL as gold standard to detect axonal loss and disability. The sensitivity and specificity of GCC, OND and ONSD were independently calculated from the ROC curve which could predict the disability.
Result:
The EDSS scores varied from 0 to 5.5. The disabled group had 10.3 ± 1.9 μm thinner RNFL (p < 0.001), 40.8 ± 15.5 μm thinner GCC (p 0.0038) as compared to the nondisabled group. OND was 3.8 ± 0.6 mm thinner (p 0.037) and ONSD was 4.6 ± 0.6 mm thinner (p 0.010) as compared to the control group. OND and RNFL were independent predictors for disability; the optimum cut-off to detect disability was 4.35mmfor OND and 12 μm for RNFL; the optimum cut-off to detect axonal loss was 4.43 mm for OND.
Conclusion: