Evidence validity of the Triage Rule-Out Using High-Sensitivity Troponin Algorithm for emergency nurses in Brazil
Thábata Larissa Agostini Dos Santos1, Kátia Cilene Godinho Bertoncello1, Keyla Cristiane do Nascimento1
1Universidade Federal de Santa Catarina (UFSC). Programa de Pós-Graduação em Gestão do Cuidado em Enfermagem. Florianópolis, Santa Catarina, Brasil.
Insights
The Triage Rule-Out Using High-Sensitivity Troponin (TRUST) algorithm was successfully adapted for Brazilian nurses, proving valid and comprehensible for cardiac risk assessment. This ensures its suitability for clinical use in Brazil.
Area of Science:
- Cardiology
- Nursing Research
- Health Services Research
Background:
- Cardiac risk assessment is crucial in emergency settings.
- The Triage Rule-Out Using High-Sensitivity Troponin (TRUST) algorithm aids in evaluating patients with chest pain.
- Validating clinical tools for diverse healthcare contexts is essential.
Purpose of the Study:
- To demonstrate the validity of the TRUST algorithm for cardiac risk assessment by nurses in Brazil.
- To ensure the cross-cultural adaptation of the TRUST algorithm meets Brazilian healthcare standards.
- To evaluate the comprehensibility and relevance of the adapted TRUST algorithm for nursing practice.
Main Methods:
- A six-stage cross-cultural adaptation process was employed, including translation, back-translation, and expert committee validation.
- Content validity was assessed using the Content Validity Index (CVI), and reliability using Cronbach's Alpha.
- A pre-test involving 31 nurses evaluated the algorithm's clarity and relevance in the Brazilian context.
Main Results:
- The adapted TRUST algorithm demonstrated high content validity (CVI > 0.90) and good reliability (Cronbach's Alpha = 0.80).
- Nurses in the pre-test found the algorithm clear, relevant, and comprehensible.
- Technical and cultural adjustments were successfully integrated into the algorithm.
Conclusions:
- The cross-cultural adaptation of the TRUST algorithm is valid and equivalent to the original version.
- The adapted algorithm is suitable for use by emergency nurses in Brazil for cardiac risk assessment.
- This validated tool can enhance the accuracy and efficiency of cardiac risk evaluation in Brazilian emergency departments.
Objective:
To demonstrate evidence of the validity of the Triage Rule-Out Using High-Sensitivity Troponin algorithm (TRUST) for cardiac risk assessment by nurses in Brazil.
Method:
A six-stage methodological study: translation; synthesis of translations; back-translation; validation by a committee of judges; pre-testing; and submission to the original author. The committee was comprised by of four bilingual translators and two specialist nurses, who assessed the translated version for semantic, idiomatic, conceptual, and cultural equivalence, as well as content validity, internal consistency and clarity. In the pre-test, 31 nurses evaluated the clarity of the algorithm. Content validity was analyzed by the Content Validity Index and reliability by internal consistency using Cronbach's Alpha.
Results:
The TRUST algorithm consists of three clinical criteria: history of chest pain, electrocardiogram, and a rapid troponin test. The adapted version demonstrated content validity and good comprehensibility, with a Content Validity Index of over 0.90 and a Cronbach's alpha of 0.80. The adaptations involved technical and cultural adjustments. In the pre-test, nurses considered the algorithm to be clear and relevant.
Conclusion:
The cross-cultural adaptation of the algorithm proved to be valid, being equivalent to the original, adapted to the Brazilian context and suitable for use by emergency nurses.
More Related Videos
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome V: Nursing Management
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Angina V: Nursing Management