Microstructure Evolution Study of the Field-Serviced Silicone Rubber Insulator via X-Ray Micro-CT Imaging
Tiantian Chen1, Fanglin Zha2, Qian Luo1
1Key Laboratory of Advanced Civil Engineering Materials (the Ministry of Education), School of Materials Science and Engineering, Tongji University, Shanghai 201804, China.
None:
Composite silicone rubber insulators are widely used in overhead transmission lines but undergo inevitable aging-induced performance degradation or failure. Understanding their aging process is crucial for optimizing manufacturing and on-site service, yet studies on microstructural changes-especially three-dimensional (3D) microstructural evolution during aging-remain scarce. This study employed X-ray micro-computed tomography (X-ray micro-CT) to characterize and compare the 3D microstructure of one fresh and one field-serviced composite silicone rubber insulator (which underwent 10 years of outdoor service). For the field-serviced insulator, key findings include the following: (1) pore number decreased (from 2200 to 1600), while pore size increased (equivalent diameter: from 3.5 ± 1.3 μm to 10.4 ± 7.2 μm); (2) porosity increased (from 0.04% to 0.69%); (3) new cracks formed (length: 100-900 μm); and (4) pore shape remained nearly unchanged relative to the fresh sample. Notably, the aging depth of the field-serviced insulator was less than 300 μm. These results clarify the 3D microstructural evolution of composite silicone rubber insulators during aging, providing a basis for improving their long-term reliability.
More Related Videos
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...