A Power-Aware 5G Network Slicing Scheme for IIoT Systems with Age Tolerance

Mingjiang Weng1, Yixuan Bai1, Xin Xie2

  • 1School of Communications and Information Engineering, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.

PubMed
Abstract

Related Concept Videos

Network Function of a Circuit01:25

Network Function of a Circuit

Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
611
Non-ohmic Devices00:51

Non-ohmic Devices

In most substances, the current flow is proportional to the voltage applied to it. A simple relationship between the values of current, voltage, and resistance is known as Ohm's law. Nonohmic devices do not exhibit a linear relationship between voltage and current. One such device is the semiconducting circuit element known as a diode. A diode is a circuit device that allows current flow in only one direction.
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
1.5K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
578
Linear time-invariant Systems01:23

Linear time-invariant Systems

A system is linear if it displays the characteristics of homogeneity and additivity, together termed the superposition property. This principle is fundamental in all linear systems. Linear time-invariant (LTI) systems include systems with linear elements and constant parameters.
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
850
Power System Distribution01:25

Power System Distribution

Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
1.0K
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
811