Related Experiment Video
Updated: Jun 29, 2026

06:58
Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
10.3K
Polish Validation and Language Adaptation of the Banff Patellofemoral Instability Instrument 2.0
Alicja Fąfara1,2, Jarosław Feluś2, Kinga Żmijewska-Jasińska1,3
1Jagiellonian University Medical College, Faculty of Health Sciences, Institute of Physiotherapy, Kraków, Poland.
Orthopaedic Journal of Sports Medicine
|November 28, 2025
Summary
The Polish version of the Banff Patellofemoral Instability Instrument 2.0 (BPII 2.0) is a reliable tool for assessing patellofemoral instability. This validated instrument enhances patient evaluation in Polish-speaking populations.
Area of Science:
- Orthopaedic research
- Clinical assessment tools
- Patient-reported outcome measures (PROMs)
Background:
- Patient-reported outcome measures (PROMs) are increasingly vital in orthopaedics.
- The Banff Patellofemoral Instability Instrument 2.0 (BPII 2.0) is a disease-specific tool for patellofemoral instability.
Purpose of the Study:
- To adapt, translate, and validate the BPII 2.0 into Polish.
- To facilitate the evaluation of Polish-speaking patients with patellofemoral instability.
Main Methods:
- The Polish BPII 2.0 was assessed in 80 patients with recurrent patellofemoral joint (PFJ) instability.
- Psychometric properties including reliability, validity, SEM, and MCID were evaluated using established scales.
- Test-retest reliability and internal consistency were measured using ICC and Cronbach's alpha.
Main Results:
- The Polish BPII 2.0 demonstrated excellent test-retest reliability (0.995) and internal consistency (Cronbach's alpha 0.95-0.96).
- Strong correlations were found between the BPII 2.0 and other PROMs (IKDC, Lysholm, Kujala, NPI).
- The SEM was 1.329 and MCID was 3.028.
Conclusions:
- The Polish version of the BPII 2.0 is a reliable and valid instrument for Polish-speaking patients with recurrent patellofemoral instability.
- This validated tool supports uniform functional assessment in international multicenter studies.
Keywords:
clinical assessment/grading scalesclinical medicine by anatomic regionclinical medicine by specialty interestkneepatellaphysical therapy/rehabilitationresearch (in vivo or in vitro)More Related Videos
Related Concept Videos
Improving Translational Accuracy
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
Improving Translational Accuracy
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
Instrument Calibration
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...