Production of in situ mixed gas phase volatile organic compound standards for sorbent tube applications
Ntoko M Leakwe1,2, Werner Welthagen2, Patricia B C Forbes1
1Department of Chemistry, University of Pretoria, Pretoria 0002, South Africa.
Abstract:
Volatile organic compounds (VOCs) are a significant class of air pollutants, as they pose a risk to human health and the environment. Precise quantification of VOCs sampled onto sorbent tubes requires gas phase standards at suitable concentrations. Herein, we present a: - gas standard preparation method for benzene, toluene, ethylbenzene and xylene (BTEX) prepared from liquid standards by means of evaporation and dynamic dilution with nitrogen - demonstration of the applicability of the LiqMix Cascade gas mix system. Repeatability and reproducibility were first successfully demonstrated via direct GC-MS analysis of generated gas mixtures. Then µg levels of generated gas standards were adsorbed onto sorbent tubes employed in active sampling and ng levels were collected onto Radiello cartridges used in passive sampling, followed by liquid extraction or thermal desorption and GC-MS analysis. Accuracy was verified by a BTEX certified reference material (99 % recovery). The LiqMix Cascade gas mix system was shown to produce precise and repeatable concentrations of BTEX gas phase standards for sorbent tube sampling applications for the first time.
More Related Videos
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Volatilization