Related Experiment Video
Updated: Jan 10, 2026

Fixation of Ultrasound Transducers for Spinal Cord Neuromodulation in Mice
Published on: August 1, 2025
Chemical Disinfection of an Accidentally Contaminated and Irreplaceable Inorganic Element During Orthopaedic Surgery
Jocelyn Corbaz1, Dominique S Blanc2, Bruno Grandbastien2
1Department of Orthopedics and Traumatology, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland.
Background:
During surgical procedures, the accidental contamination of a critical instrument or implant can jeopardize the entire operation. Resterilizing the item is not always feasible and can be time-consuming. Since extending the duration of the surgery heightens the risk of postoperative complications, it is essential to balance this risk with the risk of infection from contamination. Currently, there is no simple, safe, and quickly available method to address this issue. This study explored the efficacy of using chemical disinfection to deal with this problem.
Methods:
In part 1 of the study, 3 types of discs (cobalt-chromium, titanium, and polyethylene) were contaminated with Staphylococcus epidermidis, disinfected with use of 3 different procedures (2% chlorhexidine in 70% isopropanol alcohol, 0.9% povidone-iodine in 46% isopropanol alcohol, or 70% ethanol), and analyzed for remaining bacteria. A control group without disinfection was included. In part 2, the discs were dropped on the floor of an operating room, left on the floor for 30 seconds, and then collected before undergoing the same procedure as in part 1.
Results:
In part 1, all 3 alcohol-based disinfection procedures showed a high efficacy, as there was no growth found on any of the discs. These results were highly significant compared with those found for the control group (p < 0.01 for all). In the control group, polyethylene had the highest mean level of contamination (157.3 colony-forming units [CFUs]) and titanium had the lowest (58.4 CFUs). Part 2 confirmed the effectiveness of alcohol-based disinfection, with no growth observed in the test cultures. In the control group, polyethylene seemed to be the most prone to contamination. However, the level of contamination was low for all materials (0 to 8 CFUs per disc).
Conclusions:
In the event of accidental contamination of an essential element or implant during a surgical procedure with no possibility of replacing the element, 2 minutes of disinfection in an alcohol-based solution seems to be a safe, simple, and quick option.
Clinical Relevance:
In the event of accidental contamination of an irreplaceable inorganic element during orthopaedic surgery, we recommend soaking the element in an alcohol-based disinfectant for 2 minutes and rinsing it with saline solution.
More Related Videos
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Chemical Agents for Microbial Control
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Prevention of Further Absorption of Poison