Related Experiment Video
Updated: Jan 10, 2026

Generation and Coherent Control of Pulsed Quantum Frequency Combs
Published on: June 8, 2018
Physics-informed transformers for electronic quantum states
João Augusto Sobral1, Michael Perle2, Mathias S Scheurer3
1Institute for Theoretical Physics III, University of Stuttgart, Stuttgart, Germany. joao.sobral@itp3.uni-stuttgart.de.
Abstract:
Neural-network-based variational quantum states, particularly autoregressive models, are powerful tools for describing complex many-body wave functions. However, their performance depends on the computational basis chosen and they often lack physical interpretability. We propose a modified variational Monte-Carlo framework which leverages prior physical information to construct a complete computational many-body basis containing a reference state that serves as a rough approximation to the true ground state. A Transformer is used to parametrize and autoregressively sample corrections to this reference state, giving rise to a more interpretable and computationally efficient representation of the ground state. We demonstrate this approach in a fermionic model featuring a metal-insulator transition by employing Hartree-Fock and a strong-coupling limit to define physics-informed bases. We also show that the Transformer's hidden representation captures the natural energetic order of the different basis states. This work paves the way for more efficient and interpretable neural quantum-state representations.
Related Concept Videos
The Quantum-Mechanical Model of an Atom
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers with Off-Nominal Turns Ratios
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...