Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Disturbance observer based multiloop proportional feedback system for output voltage regulation in three phase AC to
Hosik Lee1, Dongpin Kim2, Hyun Chang Park1
1Green Mobility Team, Tenergy, 13453, Seongnam, Korea.
None:
This paper suggests a disturbance observer (DOB)-based offset-free output voltage regulator for the three-phase AC/DC power converters, taking the nonlinearity, parameter, and load uncertainties into account. The proposed multiloop controller is designed in such a way that it feeds back only proportional errors and stabilizes the output voltage and current tracking errors involving the feed-forward compensation terms driven by the DOBs. The DOBs assist the inner and outer loop controllers to ensure the performance recovery and steady-state error rejection properties, which correspond to a major contribution of this article. A three-phase 3-kW AC/DC power converter is used for experimentally verifying the efficacy of the proposed technique.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Second-order Op Amp Circuits
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
Generation of Three-Phase Voltage
As the rotor...
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Parallel RLC Circuits
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.