Background:
Failure to disinfect medical devices properly could lead to hospital-acquired infections. No-touch disinfection with ultraviolet light group C (UV-C) is increasingly used to decontaminate medical devices.
Aim:
This scoping review aimed to describe the bacterial reduction on contaminated semicritical medical devices after UV-C light disinfection.
Methods:
In December 2023, PubMed, Embase, Cochrane Library, and CINAHL were searched for articles reporting on bacterial reduction after UV-C light disinfection on semicritical medical devices. Characteristics of semicritical devices and disinfection methods were described.
Findings:
Our search found 582 articles. Eight met the inclusion criteria. Seven medical devices were identified: endoscopes without a working channel, trans-thoracic, abdominopelvic, and duplex ultrasound probes, and rectal and/or vaginal ultrasound probes. Four UV-C light disinfectors were identified. All studies reported a positive effect on bacterial reduction after UV-C light disinfection.
Conclusions:
The bacterial reduction obtained with UV-C light disinfection was not inferior compared to other disinfection methods that are currently being used. Therefore, this indicates that UV-C light disinfection could be used as a disinfection method for semicritical medical devices to reduce microbiological contamination safely. Future research must identify which UV-C light disinfector can be used safely for which medical devices as an alternative to existing disinfection methods.
More Related Videos
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Hand hygiene
Hand washing...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview