Related Experiment Video
Updated: Jan 9, 2026

LabVIEW-operated Novel Nanoliter Osmometer for Ice Binding Protein Investigations
Published on: February 4, 2013
Tunnel portal lining behavior in freeze-thaw conditions and innovative anti-freezing insulation structures
Yifan Zhang1, Liang Tang1,2, Xiangxun Kong3,4,5
1School of Civil Engineering, Harbin Institute of Technology, Harbin, 150090, China.
Abstract:
Freezing can greatly impact the capacity of tunnel linings in soil, making it essential to investigate the changes in stress state caused by frost heave. Therefore, a finite element model for frost-heave analysis is established for a cold-region tunnel portal. The research investigates the impact of lining thickness and tunnel burial depth on the distribution and trends of axial force (N) and bending moment (M) in the tunnel lining before freezing, after freezing, and after a freeze-thaw cycle. The results show that frost-heave-induced internal forces concentrate at the side wall and arch haunch, identifying these as key vulnerable sections of the portal lining. Generally, the axial force and bending moment of the lining increase after freezing and continue to increase after a freeze-thaw cycle. In addition, a composite anti-freezing insulation structure with both thermal-insulation and anti-freezing buffer functions is proposed, and the influence of its thickness on insulation performance is analyzed. Compared with the case without insulation, the composite layer reduces the maximum frozen-zone thickness in the surrounding rock by up to about 75% and decreases the transverse and longitudinal displacements/convergences of the lining by approximately 80-90%. With increasing thickness, the composite layer also lowers the frost-heave force (Ff-h) on the secondary lining and makes its distribution along the lining more uniform.
Related Concept Videos
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Thermal Expansion

