Research on the dust transportation law and cyclone air curtain dust control technology of coalface
Xiaokun Zhao1, Hongwei Wang2, Jiawei Wang3
1School of Coal Engineering, Shanxi Datong University, Datong, 037000, Shanxi, China.
Abstract:
This study investigates the large-scale dust accumulation caused by improper airflow in a coal mine roadway with mixed ventilation, aiming to understand dust distribution patterns and reduce dust concentration. A simple model was developed using SpaceClaim, and numerical simulations were performed using Ansys Fluent. The results revealed that dust filled the entire tunnel, with significant accumulation at the driver's position and the corner of the return air side. To improve the hybrid ventilation system, radial outlets were added to the inlet duct to create a vertical air curtain that intercepts dust diffusion. This air curtain, in combination with the exhaust outlet, formed a cyclone airflow moving toward the excavation face, actively reducing dust levels. Four key factors affecting dust concentration in the pedestrian breathing zone and driver's position were optimized using both single-factor and multi-factor integrated control, based on the Box-Behnken design. The optimization results indicated that the optimal dust control configuration included a guide channel width of 0.04 m, a height of 0.09 m, an axial-to-radial airflow ratio of 0.5 for the inlet duct, and an exhaust duct diameter of 1.2 m. After optimization, dust concentration in the pedestrian breathing zone decreased by 63.6%, from 1.19 × 10⁻⁴ kg/m³ to 4.33 × 10⁻⁵ kg/m³, and the dust concentration at the driver's position decreased by 78.2%, from 1.78 × 10⁻⁴ kg/m³ to 3.85 × 10⁻⁵ kg/m³. The factors influencing dust concentration in the pedestrian breathing zone, ranked by significance, were the axial-to-radial airflow ratio, duct diameter, guide channel width, and guide channel height. For the driver's position, the order of importance was axial-to-radial airflow ratio, guide channel height, guide channel width, and duct diameter. Finally, based on the similarity principle, an appropriately scaled experimental model was constructed for ventilation and dust control. The optimized airflow regulation plan was tested in air curtain dust control experiments, with results that closely matched the numerical simulations, showing an error of less than 5%.
More Related Videos
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
07:54Experimental Methods of Dust Charging and Mobilization on Surfaces with Exposure to Ultraviolet Radiation or Plasmas
Published on: April 3, 2018
Related Concept Videos
Quarrying of Stone
One common method involves using a diamond belt saw to cut large blocks from the quarry face. These blocks can be about 50 feet long and 12 feet high. After the initial vertical cut, drilling is performed at the base of the...
Load-frequency control
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...