Related Experiment Video
Updated: Jan 9, 2026

SECONDs Administration Guidelines: A Fast Tool to Assess Consciousness in Brain-injured Patients
Published on: February 6, 2021
Psychometric Evaluations of the Hospital Survey on Patient Safety Culture Version 2.0 in Ethiopia (E-HSoPSC 2.0): A
Gelana Fekadu1,2, Andrea P Marshall3,4, Rachel Muir3,5,6,7
1School of Nursing and Midwifery, Griffith University, Southport, Queensland, Australia fekadugelana4@gmail.com.
Objectives:
To evaluate the psychometric properties of the Hospital Survey on Patient Safety Culture (HSoPSC) version 2.0 in Ethiopian public hospitals.
Design:
A cross-sectional study.
Settings:
Five public hospitals in Eastern Ethiopia.
Participants:
Healthcare professionals (N=582).
Main Outcome Measure:
An adapted and contextualised version of HSoPSC 2.0 was used to conduct structural validity using exploratory and confirmatory factor analyses (EFA and CFA). Convergent and discriminant validity were evaluated through item loadings and interfactor correlations, respectively. Reliability was measured using McDonald's omega and Cronbach's alpha.
Results:
CFA indicated a poor model fit for the original 10-factor, 32-item HSoPSC 2.0 across all statistical indices: relative chi-square (χ²/df=7.71), root mean square error of approximation (RMSEA=0.108), standardised root mean square residual (SRMR=0.088), comparative fit index (CFI=0.814) and Tucker-Lewis's index (TLI=0.780). Consequently, a comprehensive EFA was conducted, which identified a revised model comprising 5-factor, 21-item. This model accounted for 62.8% of the total variance and demonstrated strong construct validity, with excellent fit indices (χ²/df=3.67, RMSEA=0.068, SRMR=0.034, CFI=0.969, TLI=0.945). Internal consistency, assessed via McDonald's omega and Cronbach's alpha, exceeded the acceptable threshold of 0.70 across all dimensions, except for Response to Error (0.66). The convergent and discriminant validity of the new model was confirmed, ensuring an accurate representation of the underlying constructs.
Conclusions:
The original HSoPSC 2.0 with 10-factor, 32-item failed to demonstrate structural validity in the Ethiopian healthcare context. In contrast, a revised 5-factor, 21-item model showed strong validity and acceptable reliability. This adapted version provides a culturally and contextually relevant tool for assessing patient safety culture in Ethiopian healthcare settings.
More Related Videos
Related Concept Videos
Surveys
Self-Report Tests of Personality
Nursing Evaluation
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Urine Studies II: Urine Culture and Sensitivity Test