An Electrophysiological Version of the Audible Contrast Threshold Test
Lisbeth Birkelund Simonsen1,2,3, Jaime A Undurraga1,4, Abigail Anne Kressner2,3
1Interacoustics Research Unit, Interacoustics A/S, Kongens Lyngby, Denmark.
Objectives:
The audible contrast threshold (ACT) test is a behavioral spectro-temporal modulation detection test used to approximate speech-in-noise performance. This study focused on the clinical reliability and validity of an electrophysiological version of the ACT test (E-ACT). The primary objectives were to evaluate the test-retest reliability of the E-ACT and explore its relationship with the behavioral ACT test and aided speech-in-noise performance. Since the E-ACT employs stimuli based on a tonal carrier while the ACT uses a noise carrier, a secondary objective was to investigate the behavioral correlation between performance with noise-carrier and tonal-carrier stimuli. We hypothesized that there would be a significant relationship between the E-ACT and the behavioral ACT.
Design:
The E-ACT utilizes the auditory change complex, a cortical response to suprathreshold sound changes, elicited here by changes between spectro-temporal modulated targets and non-modulated references. The 4-Hz temporal and two-cycles/octave spectral modulation rates were identical to those used in the ACT test. Two experiments were conducted to evaluate the E-ACT: The first experiment (experiment A) was conducted in a university setting with 18 adult participants. The second experiment (experiment B) was conducted in a hospital setting with 47 hearing-impaired adult participants. Both experiments included ACT and E-ACT measurements. In addition, experiment A incorporated behavioral tonal-ACT measurements, while experiment B included assessments of speech-in-noise performance. Electroencephalogram data were analyzed using the objective Fmpi (individualized multi-point F test) detector to determine the presence of responses.
Results:
The E-ACT test and retest were significantly correlated ( R2 = 0.62, p < 0.001). The E-ACT values correlated significantly with ACT values ( R2 = 0.18, p < 0.001), with most participants showing better thresholds for ACT compared with E-ACT. However, unexpectedly, some participants had worse ACT values compared with E-ACT. E-ACT values also correlated with aided speech-in-noise performance ( R2 = 0.09, p = 0.04). Last, ACT and tonal-ACT values were significantly correlated ( R2 = 0.53, p < 0.001), with thresholds obtained using tonal-ACT averaging 1.6 dB lower than those obtained using ACT.
Conclusions:
The E-ACT provides clinicians with an objective discrimination measure that can be utilized with patients unable to participate in behavioral tests. Both E-ACT and ACT offer insights into suprathreshold hearing, which can supplement the audiogram.
More Related Videos
Related Concept Videos
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same frequency...
Sound Intensity
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Bode Plots Construction