Multi-Isotope Internal Standardization for Inductively Coupled Plasma Mass Spectrometry
Micah X DeCourcey1, Abigail J Crossman1, Willis B Jones1
1Department of Chemistry and Biochemistry, University of North Florida, Jacksonville, Florida 32224, USA.
None:
Recent developments in trace analyte determination have evolved from the traditional relationship relating analyte signal to concentration to "multisignal" methods where both axes are measured instrumental signals. However, many multisignal methods are limited in some fashion: Some have low sample throughput, some result in poor accuracies in difficult sample matrices, and others require several significant signals for each analyte species. Multi-isotope internal standardization (MIIS) is a newly developed calibration method for inductively coupled plasma mass spectrometry (ICP-MS) that addresses the issues presented by other multisignal techniques. Multiple isotope masses for both the analyte species and several internal standards are used to build a calibration curve. Only two solutions are required to perform the calculation. Spike recovery experiments performed in complex matrices known to be problematic for ICP-MS yielded analyte recoveries of approximately 100% with relative standard deviations on the order of a few percent. MIIS was found to outperform both traditional calibration techniques as well as other multisignal methods. MIIS was validated through the determination of a suite of analytes in three certified reference materials with recoveries ranging from 85 to 111%. MIIS provides a clear advancement over other multisignal calibration techniques developed for ICP-MS, resulting in an exceptionally high number of calibration points even though only two calibration solutions are prepared.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Tandem Mass Spectrometry