Related Experiment Video
Updated: Jan 9, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Green voltammetric determination of the fungicide Fluopyram using a single-use pencil graphite electrode: Application
1Batman University, Faculty of Arts and Sciences, Department of Analytical Chemistry, 72100 Batman, Turkey.
Abstract:
Fluopyram, a broad-spectrum fungicide extensively used in agricultural systems to protect crops against a wide range of fungal pathogens, has raised increasing concern due to its potential persistence and accumulation in food and biological systems. Therefore, the development of simple, cost-effective, and highly sensitive detection strategies for monitoring Fluopyram residues is of considerable importance. In this study, we systematically explored the electrochemical properties and detection capability of Fluopyram using cyclic voltammetry (CV) and square-wave voltammetry (SWV) with a single-use pencil graphite electrode serving as the disposable working electrode. The CV measurements demonstrated that Fluopyram undergoes an irreversible oxidation process, yielding a well-defined anodic peak at approximately +1.05 V in a 0.04 M Britton-Robinson buffer solution at pH 4.0, which reflects a diffusion-controlled electron transfer mechanism. Quantification studies carried out with SWV revealed an excellent linear response over a wide concentration range from 0.04 to 1.23 μg/mL (R2 > 0.99). Notably, the method achieved a very low limit of detection of 0.009 μg/mL, underscoring the superior sensitivity of the proposed electroanalytical approach compared to many conventional methods. To evaluate its real-world applicability, the method was successfully applied to spiked urine and orange juice samples, where satisfactory recovery values confirmed its robustness in complex matrices. The electrochemical results were further validated by comparison with spectrophotometric measurements, demonstrating good consistency between the two techniques. Overall, this work introduces a disposable, rapid, and reliable electroanalytical platform for Fluopyram determination, offering promising potential for environmental monitoring, food safety assessment, and clinical applications.
More Related Videos
05:20Avocado Sample Preparation Using the QuEChERS Method with Ammonium Formate for Pesticide Analysis
Published on: December 8, 2023
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...