Related Experiment Video
Updated: Jan 9, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Optimization of Normal Tissue Objectives (NTO) in HyperArc Radiosurgery for Brain Oligometastases: A Systematic
Huipeng Meng1, Yanlong Zhang2, Jinghao Duan3
1Department of Radiation Oncology, Tianjin First Central Hospital, School of Medicine, Nankai University, Tianjin, China.
Abstract:
ObjectiveTo systematically investigate the impact of adjusting the relative weight of the built-in Stereotactic Radiosurgery Normal Tissue Objective (SRS-NTO) on dosimetric quality, plan complexity, and delivery efficiency in HyperArc™ stereotactic radiosurgery (SRS) for brain oligometastases.MethodsIn this retrospective planning study, a cohort of 20 patients with 1-3 brain oligometastases was analyzed. For each case, six distinct HyperArc plans were designed and optimized using the Varian Eclipse™ Treatment Planning System. To precisely isolate its impact, the relative weight of the SRS-NTO to the PTV objective was systematically varied across six levels-50%, 75%, 100% (default), 125%, 150%, and 200%-while all other planning parameters were held constant. A comprehensive comparative evaluation was then performed to assess the plans across four key domains: (i) dosimetric quality, evaluated by metrics including the Paddick Conformity Index (CI), Gradient Index (GI), and dose to Organs at Risk (OARs); (ii) plan complexity, characterized by various modulation and aperture-based indices; (iii) delivery efficiency, primarily quantified by the total Monitor Units (MUs); and (iv) physical deliverability, verified via Gamma analysis.ResultsIncreasing NTO weight did not significantly alter dosimetric quality; key metrics for CI, GI, and OAR sparing remained statistically equivalent (p > .05). Conversely, higher NTO weights prompted a significant reduction in total MUs (p < .001) that reached an optimum at the 150% setting, and enhanced plan deliverability, evidenced by significantly higher Gamma passing rates under stricter verification criteria. An inflection point was observed beyond the 150% setting, with higher weights leading to degraded plan complexity and efficiency. Strategies within the 125% to 150% range demonstrated a superior balance, achieving optimal dosimetric trends while maximizing gains in efficiency and precision.ConclusionIn HyperArc SRS for brain oligometastases, moderately increasing the SRS-NTO weight from the default 100% into the 125% to 150% range is a superior clinical strategy. This adjustment significantly enhances treatment efficiency and delivery precision by reducing plan complexity, without compromising dosimetric quality, thereby achieving a superior overall performance.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018