Photoelastic analysis of stress distribution in single and three-unit implant-supported prostheses with different
Abbas Zahoui1, Marcelo Coelho Goiato2, Rodrigo Antonio de Medeiros3
1Faculty of Dentistry, University Sagrado Coração - USC, Bauru, SP, Brazil.
Background:
The accurate fit between the dental implant and the prosthetic abutment is crucial for the stability of the entire prosthetic-implant system, providing a better distribution of the occlusal load to the surrounding bone. To improve stress distribution between the implant and bone, various types of internal connection implants have been introduced. However, few studies are available on the biomechanical behavior of these connections. This study investigated the stress distribution in screwed implant-supported prosthesis with different implant‒abutment connections using a photoelastic analysis.
Methods:
Eight photoelastic models were fabricated in PL-2 resin and divided according to the different types of internal connections: Morse taper (MT), internal Morse hexagon (IMH), Morse taper hexagon (MTH), and frictional Morse taper (FMT) implants (3.75×11.5 mm), and the number of crowns (single and 3-unit pieces). Models were positioned in a circular polariscope, and 100-N axial and oblique (45º) loads were applied to the occlusal surface of the crowns using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using Adobe Photoshop software.
Results:
Under axial loading, the number and distribution of high-intensity fringes did not differ among groups for both crown types (single and splinted 3-element). Low stress values were noted at the implant apex. The oblique loading increased the number of fringes for all groups. In conclusion, the internal connection tested in this study did not affect the number and distribution of stress.
Conclusion:
The different types of internal connections provided better stability for the implant‒prosthesis set, which improved stress distribution when the prosthetic pillar was loaded, with the Morse cone friction system showing less stress. Oblique loading resulted in a higher stress concentration than axial loading.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
Related Concept Videos
Transformation of Plane Stress
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Stress Concentrations
Applications of Stress
The...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...