Related Experiment Video
Updated: Jul 14, 2026

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
A Southeast Asian Experience in Biodegradable Implants: Tips and Tricks for Radiological Findings
Teddy Cheong1, Karen Fernandes2, Joe Francis2
1Orthopedic Surgery, Changi General Hospital, Singapore, SGP.
Biodegradable magnesium screws offer orthopedic advantages over metal implants. Understanding their unique imaging patterns is crucial for accurate diagnosis and avoiding misinterpretation of normal degradation.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Radiology
Background:
- Nondegradable metallic implants (e.g., titanium, steel) are standard in orthopedics but cause complications like hardware removal surgery and imaging interference.
- Biodegradable magnesium-based implants present an innovative alternative, offering biocompatibility, osteoconductivity, and bone-like elastic modulus.
- MAGNEZIX compression screws, the first approved magnesium implant, are widely used, particularly in foot and ankle surgery, with positive outcomes.
Purpose of the Study:
- To familiarize radiologists and clinicians with the expected imaging findings of magnesium-based implants.
- To reduce misdiagnosis and unnecessary advanced imaging associated with biodegradable implant biodegradation.
- To provide essential knowledge for interpreting radiological images of patients treated with MAGNEZIX screws.
Main Methods:
- Retrospective evaluation of pre-operative and post-operative radiological images from 75 patients.
- Patients treated with MAGNEZIX screws for foot and ankle injuries between 2020-2022 at Changi General Hospital.
- Detailed presentation of seven selected cases with serial post-operative images, highlighting key learning points.
Main Results:
- Analysis focused on recognizing the normal evolution and degradation patterns of magnesium implants.
- Demonstrated the importance of correlating imaging findings with clinical assessment.
- Highlighted potential pitfalls in interpreting imaging of biodegradable implants.
Conclusions:
- Biodegradable MAGNEZIX screws are effective alternatives to metallic orthopedic implants.
- Knowledge of expected imaging findings is essential to prevent misdiagnosis and reduce unnecessary advanced imaging.
- Effective multidisciplinary communication and staying updated on degradable implant literature are vital.
More Related Videos
14:49Direct and Indirect Culture Methods for Studying Biodegradable Implant Materials In Vitro
Published on: April 15, 2022
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...