Palpation versus hand‑held Doppler for identifying lower‑limb peripheral arteries: Time‑efficiency and reliability in
Rio Nakamine1, Ryoga Matsumoto1, Misaki Matsumoto1
1Department of Rehabilitation, Faculty of Health Sciences, Naragakuen University, Nara, Japan.
Background:
Bedside lower‑limb vascular assessment commonly relies on pedal pulse palpation or hand‑held Doppler, yet their relative time‑efficiency and the reliability of Doppler measurements in novices are unclear.
Methods:
Twenty healthy adults were examined by three undergraduate raters without prior Doppler experience. For dorsalis pedis, anterior tibial, and posterior tibial arteries, each rater performed three trials with palpation and with a hand‑held continuous‑wave Doppler. Primary outcomes were time‑to‑identification and identification success; for Doppler, peak systolic velocity (PSV) reliability was evaluated (intra‑ and inter‑rater intraclass correlation coefficients [ICC] and Bland-Altman).
Results:
Differences were defined as Doppler-palpation (positive values indicate longer time for Doppler). Palpation was faster than Doppler for dorsalis pedis (Hodges-Lehmann +6.47 s, 95% confidence interval [CI]: 2.40-8.00; p = 0.004) and posterior tibial arteries (+6.38 s, 1.10-13.61; p = 0.012). The anterior tibial artery was never identified by palpation but was identified by Doppler in all participants (exact McNemar p = 1.91 × 10⁻⁶). Doppler reliability for dorsalis pedis PSV was excellent within raters (ICC [3.1]: 0.926-0.971) and between raters (ICC [2.1]: 0.966), with small mean biases and narrow limits of agreement.
Conclusions:
In healthy adults, palpation enables faster identification of dorsalis pedis and posterior tibial pulses, whereas the deeper anterior tibial artery is consistently detected only with Doppler. Doppler‑derived PSV shows excellent reproducibility even among novice examiners. These findings provide methods-level evidence to inform protocol design and training; validation in patient populations is required before any workflow recommendations.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure in the Leg
Preparation:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: