Fatigue Performance and Failure Loads of Composition-Gradient Multilayer Zirconia: Partial-Coverage Restorations
F A Spitznagel1, A Marksteiner1, L S Prott1,2
1Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
Summary
Composition-gradient multilayer zirconia restorations showed high fatigue resistance. Ultrathin partial-coverage restorations (PCRs) had higher failure loads than crowns, while both types are viable at greater thicknesses.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Restorative Dentistry
Background:
- Monolithic zirconia restorations are increasingly used in dentistry.
- Understanding the mechanical behavior of different zirconia formulations and designs is crucial for clinical success.
- Composition-gradient multilayer zirconia offers potential advantages in mechanical properties.
Purpose of the Study:
- To evaluate the fatigue resistance and failure load of monolithic composition-gradient multilayer zirconia restorations.
- To compare the influence of restoration type (partial-coverage vs. crown) and ceramic thickness on mechanical performance.
- To assess the suitability of these restorations for clinical application.
Main Methods:
- Seventy-two CAD/CAM-fabricated zirconia restorations were tested.
- Restorations were categorized by type (partial-coverage restoration [PCR] or crown [C]) and ceramic thickness (0.5, 1.0, or 1.5 mm).
- Specimens underwent thermomechanical fatigue followed by single load to failure testing.
Main Results:
- All specimens survived fatigue, with a 97.22% overall success rate.
- Ultrathin (0.5 mm) PCRs exhibited significantly higher failure loads than ultrathin crowns.
- At 1.5 mm thickness, crowns showed higher failure loads than PCRs, while no significant difference was found at 1.0 mm.
Conclusions:
- Ultrathin (0.5 mm) partial-coverage zirconia restorations demonstrate superior failure loads compared to crowns.
- Both partial-coverage restorations and crowns are mechanically viable at thicknesses of 1.0 mm and 1.5 mm.
- Composition-gradient multilayer zirconia is suitable for minimally invasive PCR molar restorations, with a minimum thickness of 1.0 mm recommended for single crowns.
Related Concept Videos
Fatigue Strength of Concrete
515
Fatigue, in the context of materials science and engineering, refers to the weakening or failure of a material caused by repeatedly applied loads, even if these loads are below the strength limit of the material. Fatigue strength in concrete is a critical property that influences its durability and longevity. Concrete can fail in two ways due to fatigue. Static fatigue or creep rupture occurs under a constant load or one that increases slowly. The other failure mode is due to cyclical or...
515
Fatigue
782
Fatigue occurs when materials rupture under repeated or fluctuating loads, even at stress levels far below their static breaking strength. It typically results in brittle failure, even for ductile materials. It is a critical consideration in designing machines and structural components subjected to repetitive or varying loads. The nature of these loadings can range from fluctuating loads like unbalanced pump impellers causing vibrations to repeatedly bending a thin steel rod wire back and forth...
782
Abrasion Resistance of Concrete
481
Abrasion resistance is an essential characteristic of concrete that determines its durability and longevity under various wear conditions. Concrete surfaces are vulnerable to different types of abrasion. For instance, surfaces may wear down due to the constant movement of vehicles or be eroded by solids carried in water, as seen in concrete canal linings. Specific tests are conducted to measure the abrasion resistance of concrete.
One such test is the revolving disc test, where three plates...
One such test is the revolving disc test, where three plates...
481