Continuous non-invasive measurement of core vital signs in the hospital ward
Abstract:
Vital sign monitoring in the hospital ward is critical to provide valuable information to predict patient deterioration or treatment efficiency. The frequency at which patients' vitals should be assessed is a compromise between insufficient monitoring and work overload.This project, in collaboration with the company Rheo, aims at providing a photoplethysmography based solution for continuous monitoring of oxygen saturation (SpO2), heart rate, blood pressure and respiratory rate using a unique and non-invasive upper-arm-worn device.We collected a relevant dataset to evaluate the accuracy of the estimated vital signs. Performance of vital sign estimation algorithms met medical requirements. Overall performances obtained were 2.06% root mean square error (RMSE) for SpO2, 0.88 cpm (cycle per minute) RMSE for respiratory rate, an error of -0.1 ± 7.8 mmHg for the systolic blood pressure estimate and 0.2 ± 4.3 mmHg for the diastolic blood pressure estimate and 2.08 bpm (beat-per-minute) RMSE for heart rate.The study demonstrates the feasibility of embedding algorithms for measuring various vital signs into one single non-invasive wearable device and reaching expected medical requirements.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...