Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Image-free system for non-contact cardiopulmonary monitoring in supine posture
Abstract:
Conventional contact-sensors for continuous vitals monitoring is uncomfortable for patients, especially in the post surgery day care units. We propose an image-free and completely non-contact hospital bed-based system to monitor cardiopulmonary activity while resting. The system utilizes the concept of respiratory sinus arrhythmia (RSA), which is the variation in heart rate in synchronism with breathing. This information is used to extract the respiratory information from the inter-beat intervals of the J peaks (J-J intervals) of the ballistocardiogram signals. This provides a viable option for continuous monitoring without the need for more modalities, complex processing, and affecting caregiving. Since the system does not have any imaging components, it is free from errors due to ambient light, insufficient illumination, and line-of-sight (LOS) mismatches. Also, since the system does not retain any patient-specific information, it does not raise any privacy concerns. The proposed system showed a strong agreement between the estimated and ground truth values with a pearsons's correlation coefficient (r) of 0.86 and 0.92 for respiratory rate and heart rate values respectively. The system also had a root mean squared error (RMSE) of 3.2 bpm for heart rate values and 2.8 brpm for respiration values, and a mean absolute error (MAE) of 2.8 bpm for heart rate values and 1.6 brpm for respiratory rate values.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Holter Monitor: 24-Hour Monitoring
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...