Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Personalized Cuffless Blood Pressure Measurement based on Arterial 0D-1D Model with Carotid Flow and Radial Pulse
Abstract:
Cuffless blood pressure (BP) shows great potential to revolutionize the management of hypertension-one of the most modifiable risk factors of cardiovascular diseases. Extensive studies take advantage of peripheral photoplethysmogram (PPG) signal for cuffless continuous BP measurement, and demonstrated reasonable performance. However, the PPG signal is usually acquired from a single locality and it only reveals the information of blood volume change, resulting in poor generalization across different individuals for BP estimation. In this study, we propose a coupled arterial 0D-1D model for brachial BP estimation, incorporating carotid blood flow and radial artery PPG signals that represent both central and peripheral cardiovascular information for personalized modeling. We validated the proposed model on the Pulse Wave Dataset data that include 4374 samples. The results show that the mean error ± standard deviation for the estimated systolic and diastolic BP were 1.39 ± 2.53 mmHg and -0.47 ± 2.39 mmHg, respectively. Comparison with machine learning models such as decision tree and random forest also demonstrated that the 0D-1D BP estimation model could integrate multimodal signals and combine with blood flow path information to make personalized BP measurement.
More Related Videos
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.