Denoising of Heart Sound Recordings A self-supervised approach for real non-stationary noise conditions
Related Experiment Video
Updated: Jan 9, 2026

Semi-automated Optical Heartbeat Analysis of Small Hearts
Published on: September 16, 2009
Abstract:
In the context of assisting patients with heart failure, implantable devices measuring cardiac mechanical activity offer promising solutions for remote autonomous monitoring of individuals at risk. However, cardiac vibration signals acquired by these implants are often subject to various specific noises associated with sensor placement and patient activity. In this paper, we propose a novel supervised method for cleaning noise-corrupted sequences and improving their pathophysiological interpretation. Our approach involves modeling the characteristics of both clean cardiac components and noise contributions through a qualitative classification of recordings. These models are then utilized to generate a controllable database, which trains a deep-learning-based denoising autoencoder. We have tested this procedure on a preclinical prototype implanted subcutaneously in four healthy pigs. We evaluate the denoising performance of our method using various quantitative and qualitative metrics. Our cleaning process, by reducing the mean relative error by up to a factor of five and enhancing the contrast of heart sounds to levels similar to their clean counterparts, improves the accuracy of physiological estimates such as heart rate or systole and diastole durations.Clinical relevance- Our approach consistently increases the number of signals suitable for further medical analysis. The proposed combination of a data-driven training database and a machine-learning denoising algorithm can significantly improve the quality and reliability of heart sound signals.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Sampling Continuous Time Signal
In the...