Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Smartphone Dual-Camera based Blood Pressure Screening Using Pulse Transit Time Between Ear and Finger
Abstract:
The advancement of smartphones, particularly the optical cameras and embedded sensors, has enabled the acquisition of physiological signals from the human body for health screening. This study proposes a framework using a smartphone's dual-camera system to synchronously collect photoplethysmographic (PPG) signals from finger and ear for estimating blood pressure (BP). By calculating the Pulse Transit Time (PTT) between PPG signals from the ear and finger, and extracting heart rate and heart rate variability parameters, we estimate systolic and diastolic BP based on two personalized regression models. These estimates are then compared with the cuff-based reference. Experiments involving 15 participants demonstrated that the best performance was achieved using the physiological information extracted from PPG, such as PTT and heart rate, in combination with a random forest regression model. The mean absolute error for systolic/diastolic BP is 3.74 mmHg and 2.73 mmHg, with Pearson correlation coefficient of 0.877 and 0.868, validating the feasibility of BP screening using a smartphone dual-camera system.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure