Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Intraoperative neuromonitoring reduces vocal cord injury in open thyroid cancer surgery: results from a randomized
Yunchao Xin1, Yanbin Liu1, Yachao Liu1
1Otolaryngology-Head and Neck Surgery Department, The First Affiliated Hospital of Hebei North University, No.12 Changqing Road, Qiaoxi, Zhangjiakou, 075000, Hebei, China.
Background:
Intraoperative neuromonitoring (IONM) has been increasingly used in thyroid surgery, yet its clinical value remains controversial.
Objectives:
This randomized controlled trial aimed to evaluate the efficacy and safety of IONM in thyroid cancer surgery.
Methods:
The standardized four-step monitoring protocol was used in the IONM group. Primary endpoints included RLN injury rates and postoperative voice function recovery. Secondary endpoints included surgical parameters (operation time, blood loss), complication rates, and oncological outcomes. Voice function was assessed using VHI-10 scoring and maximum phonation time (MPT). Patients were followed up for a median of 6 months.
Results:
The IONM group demonstrated significantly lower rates of temporary vocal cord paralysis (2.0% vs 10.0%, P = 0.038) and higher nerve identification rates (100% vs 96.0%) compared to the control group. Voice function recovery was notably faster in the IONM group, with smaller changes in VHI-10 scores (Δ = 4.2 ± 1.5 vs 7.6 ± 2.1, P < 0.001) and shorter MPT recovery time (14.2 ± 3.5 vs 25.6 ± 5.2 days, P < 0.001). Although operation time was longer in the IONM group (125.6 ± 18.3 vs 108.4 ± 15.7 min, P < 0.001), no significant differences were found in blood loss (45.3 ± 12.6 ml vs 48.7 ± 13.2 ml, P = 0.183), complication rates, or oncological outcomes between the groups.
Conclusion:
IONM technology greatly lowers the risk of temporary recurrent laryngeal nerve injury and speeds up voice function recovery in thyroid cancer surgery. Although operation times are slightly extended, the technique is safe and preserves oncological integrity.