Related Experiment Video
Updated: Jan 9, 2026

Closure of a Patent Foramen Ovale PFO: An Intervention Sequence
Published on: December 23, 2022
Unconventional Ductal Flow Restriction and Iatrogenic Pseudoaneurysm Plug Closure in Pulmonary Atresia With Intact
John Wiegand1, James Thompson2
1Department of Pediatrics, University of South Florida, Tampa, Florida, USA.
Background:
Pulmonary atresia with intact ventricular septum (PA/IVS) and right ventricular-dependent coronary circulation pose management challenges requiring creative transcatheter solutions when surgery is unfeasible.
Case Summary:
A small-for-gestational-age term neonate with PA/IVS and right ventricular-dependent coronary circulation developed hemodynamic instability after patent ductus arteriosus stenting, requiring deployment of a modified Medtronic Microvascular Plug within the patent ductus arteriosus stent to restrict pulmonary overcirculation. A left external iliac artery pseudoaneurysm was subsequently closed using a 4-mm Konar-A vascular plug.
Conclusions:
This case underscores the delicate balance between management of pulmonary over- and undercirculation in neonates with PA/IVS and highlights creative transcatheter strategies used to address these dual hemodynamic dilemmas. Early recognition of at-risk anatomy, and consideration for cardiac transplantation, are essential for survival in these high-risk patients.
Take-Home Message:
Unconventional transcatheter strategies may be essential in managing high-risk neonates with congenital heart disease.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm I: Introduction