Related Experiment Video
Updated: Jan 9, 2026

Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014
Establishment of UPLC-MS/MS Method for Determining the Content of Memantine in Rat Plasma and Its Pharmacokinetic
Jinwen Wang1,2, Chang Wang1, Yingfei Zhang1
1Department of Pharmacy, the 940th Hospital of Joint Logistics Support Force of Chinese People's Liberation Army, Lanzhou, China.
Abstract:
This study aimed to establish an UPLC-MS/MS method for determining memantine (MM) in rat plasma and to investigate its pharmacokinetic variations at different altitudes. MM was separated on a Hypersil Gold C18 column using a gradient elution method and detected by selected reaction monitoring (SRM). Sixteen fasted SD rats were randomized into low- and high-altitude groups (n = 8 each) and orally administered MM at 5 mg/kg. Serial blood samples were collected at 0-, 0.08-, 0.25-, 0.5-, 0.75-, 1-, 2-, 4-, 8-, 12-, 24-, 36-, and 48-h postdose for pharmacokinetic analysis. Compared with the low-altitude group, the high-altitude group exhibited a 72.15% increase in the area under the plasma concentration-time curve (AUC(0-∞)), a 39.97% reduction in apparent volume of distribution (Vz/F), the apparent clearance (CLz/F) decreased by 41.99%, the peak concentration (Cmax) increased by 131.52%, while the half-life (t1/2) and time to peak concentration (Tmax) showed no significant changes. In conclusion, high-altitude hypoxia significantly affects MM metabolism in rats, potentially posing a risk of drug accumulation in plasma. The research findings provide a reference for the rational use of MM in high-altitude regions.