BpBLS: A Knowledge-Embedded Bi-Incremental Broad Learning System for Wearable Cuffless Blood Pressure Estimation
Abstract:
Cuffless blood pressure (BP) measurement has gained increasing attention due to the global aging population. Data-driven approaches have shown high accuracy for cuffless BP estimation. However, when deployed on wearable devices, they often suffer from being time-consuming because a complete retraining process is required if the training samples or structure need to be expanded. To address these issues, we propose a Knowledge-embedded Bi-incremental Broad Learning System (BpBLS) for cuffless BP estimation using biosignals collected from wearable devices.With a flat structure, BpBLS can be updated flexibly and quickly without retraining the entire model for incremental biosignals and/or training samples. In BpBLS, a novel Pulse Pressure Regularization (PPR) method is proposed to comprehensively capture the BP knowledge, which is then embedded into the system to enhance its accuracy. Experimental results demonstrate that BpBLS exhibits superior performance in both estimation accuracy and computational efficiency compared to the state-of-the-art approaches. For the CAS-BP dataset, the estimation error is 0.60 $\pm$ 8.44 for systolic BP (SBP) and 0.29 $\pm$ 6.45 for diastolic BP (DBP); while for the Aurora-BP dataset, the estimation error is -0.32 $\pm$ 8.46 mmHg for SBP and 0.05 $\pm$ 6.65 mmHg for DBP. More importantly, the training time for both datasets is less than ten seconds, and the computational efficiency is improved by an order of magnitude compared to traditional machine learning methods. Our work will serve as a novel flexible and lightweight framework for cuffless BP measurement.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)