Related Experiment Video
Updated: Jan 9, 2026

The Effect of Charging and Discharging Lithium Iron Phosphate-graphite Cells at Different Temperatures on Degradation
Published on: July 18, 2018
Early prediction of lithium-ion battery degradation with a generative pre-trained transformer
Jincheng Hu1,2, Pengyu Fu1,2, Zhongbao Wei3
1School of Automotive Studies, Tongji University, Shanghai, China.
Abstract:
The early detection of degradation in lithium-ion batteries (LIBs) is crucial for effective predictive maintenance and recycling. However, accurately predicting the future degradation of LIBs in early stage is challenging due to the barely noticeable performance changes at initial charging cycles and the long-term nonlinear degradation pattern. In this work, we propose a two-stage early-stage degradation prediction method, BatteryGPT, which employs a Generative Pre-trained Transformer (GPT) to autoregressively predict the charging data of entire lifecycle and a state-of-health (SOH) estimator to correlates the predicted charging data with ageing features in LIBs. The validation demonstrates that BatteryGPT can predict the future LIB degradation with high accuracy using early charging data, before any capacity degradation is evident. Predicting with the first 30% of the battery lifetime, BatteryGPT significantly outperforms baselines, achieving a root mean square error (RMSE) of 0.213% for SOH variation prediction, and mean absolute percent errors (MAPE) of 2.30% and 1.18% for knee point and EOL predictions. Even predicting with the first 5% of lifetime charging data, BatteryGPT demonstrates strong early-stage prediction performance.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Transformers with Off-Nominal Turns Ratios
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's tangential...