Modeling Filtration Flow Rate in Peristaltic Pump Systems for High-Viscosity Bovine Serum Albumin: A Multivariate

Jianwei Chang1, Yu Zhang1, Fang Zhang1

  • 1WuXi Biologics, 190 Hedan Road, Waigaoqiao Free Trade Zone, Shanghai, 200131, China.

PubMed
Abstract

Related Concept Videos

Pipe Flowrate Measurement: Problem Solving01:28

Pipe Flowrate Measurement: Problem Solving

A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is achieved...
789
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution01:09

One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution

The one-compartment open model is a simplified approach used in pharmacokinetics to understand the distribution and elimination of a drug administered through an intravenous bolus. This model assumes rapid drug dispersal throughout the body and elimination using a first-order process. Key pharmacokinetic parameters, such as the elimination rate constant (k), half-life (t1/2), and the apparent volume of distribution (Vd), can be estimated from this model. The elimination rate is calculated...
814
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
315
Viscosity of Fluid01:19

Viscosity of Fluid

Viscosity measures the resistance a fluid offers to flow and deformation. It results from internal friction between layers of fluid moving relative to one another. Dynamic viscosity, denoted by the Greek letter mu (μ), quantifies the force needed to move one fluid layer over another. For Newtonian fluids like water and air, the relationship between the shearing stress and the rate of shearing strain is linear, meaning their viscosity remains constant regardless of the applied stress.
1.1K
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance00:56

One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance

Clearance is a key pharmacokinetic parameter that quantifies the volume of body fluid from which a drug is entirely removed within a specific time frame. It is crucial in assessing how a drug is eliminated from the body and has critical clinical applications.
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
327