Related Experiment Video
Updated: Jan 9, 2026

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
Published on: January 29, 2018
CineECG detects abnormal electrical activity in the 12-lead ECG of preclinical plakophilin-2 variant carriers
Iris van der Schaaf1,2, Manon Kloosterman1,2, Anton P M Gorgels3
1Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands.
Background:
Carriers of (likely) Plakophilin-2 pathogenic variants (PKP2-(L)PV) are at risk of developing arrhythmogenic cardiomyopathy. Early disease detection is crucial because life-threatening arrhythmias may occur early. CineECG is a novel electrocardiogram (ECG) analysis tool that reconstructs the average trajectory of ventricular electrical activity.
Objective:
The study aimed to describe the electrical depolarization and repolarization CineECG trajectories in PKP2-(L)PV carriers with a normal ECG as per evaluation of 2 cardiologists, who meet no Task Force Criteria other than their PV.
Methods:
PKP2-(L)PV carriers were 2:1-matched to control subjects, who had atrioventricular nodal reentry tachycardia but no other cardiac abnormalities. Sinus rhythm ECGs of controls were used to create a normal distribution of trajectories. PKP2-(L)PV carriers' trajectories were compared with the normal distribution. A trajectory was considered abnormal if it fell less than 95% within the normal distribution.
Results:
Overall, 104 subjects were included (age 24 years [19-36], 43% men): 37 PKP2-(L)PV carriers and 67 controls. Depolarization and repolarization trajectories were abnormal in 51% and 24% of carriers, respectively. In carriers with abnormal depolarization trajectories, significant differences were observed in the direction of the initial depolarization trajectory when compared with controls in the inferior-superior axis (P = .005) and posterior-anterior axis (P = .020). In the left-right axis, the direction significantly differed from carriers with a normal trajectory (P = .020).
Conclusion:
Abnormal electrical activity was identified in over half of preclinical PKP2-(L)PV carriers with a normal ECG. CineECG could be a sensitive tool to unveil early, subtle abnormalities in ventricular electrical activity that would otherwise not be detected.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...

