Related Experiment Video
Updated: Jan 9, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Toward Noninvasive Assessment of Arterial Stiffness: Regression Modeling From Radial-Tibial Pulse Wave Features
None:
In the last decade, research in developing systems for monitoring clinical parameters has grown exponentially, driven by the increasing demand for continuous and remote observation. Monitoring cardiovascular diseases (CVDs) is crucial, as they remain the leading cause of mortality worldwide. Pulse Wave Velocity (PWV) is a key clinical indicator for assessing arterial stiffness, highly correlated with CVDs. Current methods for measuring PWV require acquiring pulse wave signals at the carotid and femoral sites, configurations that are widely validated in the literature. However, accessing these specific anatomical points presents a significant challenge for developing wearable devices for continuous or home-based PWV monitoring. The present study proposes an innovative approach using a regression algorithm to predict the carotid-femoral PWV value from pulse waves acquired at more accessible sites, including the carotid, radial, and tibial, compatible with wearable use. The study was conducted on a cohort of 90 voluntary healthy participants at the Candiolo Cancer Institute FPO-IRCCS. The best-performing carotid-radial models show a mean error (ME) of less than 0.1 m/s, with a standard deviation error (SDE) below 1 m/s. Similarly, the radial-tibial models exhibit a mean error of the same magnitude but with an even smaller standard deviation error, below 0.9 m/s. These results highlight the strong predictive capabilities of the developed models, offering promising prospects for future clinical implementation aimed at non-invasive and potentially continuous vascular health monitoring.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Blood pressure in the Leg
Preparation: