A randomised controlled trial of high-flow nasal oxygen compared with standard oxygen delivery in obese patients
Ned Douglas1,2, Reny Segal1,2, Kane O'Donnell3
1Department of Anaesthesia and Pain Management, the Royal Melbourne Hospital, Parkville, Australia.
Background:
Arterial haemoglobin oxygen desaturation is common during gastroscopy and is associated with patient harm. Obesity increases the risk of desaturation during gastroscopy. High-flow nasal oxygen may reduce the risk of desaturation, but data are lacking.
Methods:
We conducted a single-centre, parallel group, randomised controlled trial of high-flow nasal oxygen at 50-70 l/min compared with oxygen via nasal prongs 4-10 l/min, enrolling adults having gastroscopy procedures who had a body mass index greater than 30 kg/m2. The primary outcome was the incidence of desaturation, defined as any peripheral oxygen saturation less than 90% during the procedure.
Results:
We recruited 150 participants (75 in each group). The mean body mass index was similar in each group (35 vs. 36 kg/m2). High-flow nasal oxygen reduced the incidence of desaturation compared with standard oxygen therapy (three (4%) vs. 14 (19%), P = 0.005), and increased the median minimum peripheral oxygen saturation (98% (interquartile range 92-97%) vs. 94% (interquartile range 97-100%), P < 0.001). Fewer patients administered high-flow oxygen required airway interventions (39 (52%) vs. 58 (77%), P < 0.001), while the number of patients requiring interruption to the procedure for airway management were similar in each group (seven (9%) vs. five (7%), P = 0.57). High-flow nasal oxygen was associated with a higher risk of apnoea compared with standard oxygen delivery (17 (23%) vs. six (8%), P = 0.013), and a similar risk of arrhythmias existed between the groups (two (3%) vs. one (1%), P = 0.56).
Conclusion:
High-flow nasal oxygen reduced the incidence of desaturation during gastroscopy in obese patients.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History